Purpose The purpose was to assess image quality of portal-venous phase dual-energy computed tomography (DECT) for liver lesions. Methods We performed 120-kVp-equivalent linear-blended (LB) and monoenergetic reconstructions from 40 to 190 keV by standard (VMI) and advanced virtual monoenergetic (VMI+) methods. Diagnostic performance, and quantitative and qualitative image analyses were assessed and compared. Results Liver contrast to noise ratio peaked at 40 keV_VMI+, while image quality and reader preference peaked at 50 keV_VMI+. 50 keV_VMI+ scored overall higher diagnostic performance: lesion sensitivity 95.4% vs. 83.3% for both 75 keV_VMI and LB. Conclusions DECT improves assessment of hypoenhancing liver lesions on portal venous phase. 50 keV_VMI+ demonstrated the highest image quality and diagnostic performance over VMI and LB.

Can dual-energy computed tomography improve visualization of hypoenhancing liver lesions in portal venous phase? Assessment of advanced image-based virtual monoenergetic images

LAGHI, ANDREA;
2017-01-01

Abstract

Purpose The purpose was to assess image quality of portal-venous phase dual-energy computed tomography (DECT) for liver lesions. Methods We performed 120-kVp-equivalent linear-blended (LB) and monoenergetic reconstructions from 40 to 190 keV by standard (VMI) and advanced virtual monoenergetic (VMI+) methods. Diagnostic performance, and quantitative and qualitative image analyses were assessed and compared. Results Liver contrast to noise ratio peaked at 40 keV_VMI+, while image quality and reader preference peaked at 50 keV_VMI+. 50 keV_VMI+ scored overall higher diagnostic performance: lesion sensitivity 95.4% vs. 83.3% for both 75 keV_VMI and LB. Conclusions DECT improves assessment of hypoenhancing liver lesions on portal venous phase. 50 keV_VMI+ demonstrated the highest image quality and diagnostic performance over VMI and LB.
2017
dual-energy ct
liver lesion
monoenergetic
portal venous phase
adult
aged
female
humans
image processing
computer-assisted
liver
liver neoplasms
male
middle aged
portal vein
prospective studies
radiography
dual-energy scanned projection
reproducibility of results
sensitivity and specificity
signal-to-noise ratio
tomography
x-ray computed
radiology
nuclear medicine and imaging
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/100875
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 51
  • ???jsp.display-item.citation.isi??? 48
social impact