The aim of our study was to evaluate the sensitivity, specificity and diagnostic accuracy of Magnetic Resonance Cholangiography (MR-CP) in patients with suspected choledocholithiasis. Sixty-two patients (mean age: 56.3 years) previously submitted to US, were examined with MRCP. MR exams were performed with an 0.5 T superconductive magnet (Gyroscan T5-II; Philips, Medical System, Best, NL) and a body coil. 3D-TSE sequences (TR/TE/ETL = 5.000/244/45 ms) were acquired, with 14 min 10 sec acquisition time. In the last 21 patients, acquisition time was reduced down to 3 min, by optimizing the parameters as follows: TR/TE/ETL = 3.000/700/128 ms. The images, obtained on the coronal plane, were then reconstructed with the MIP algorithm. MRCP images were studied both as MIP reconstructions and as single slices. The diagnosis was always compared with endoscopic or percutaneous findings. MRCP images were of diagnostic quality in all cases, with 91.7% sensitivity, 100% specificity and 96.8% diagnostic accuracy. MRCP had 100% positive predictive value and 95% negative predictive value. In conclusion, this technique is extremely useful to examine the patients with obstructive jaundice secondary to lithiasis.

[Lithiasis of the common bile duct: the role of cholangiography and magnetic resonance]

LAGHI, ANDREA;
1996-01-01

Abstract

The aim of our study was to evaluate the sensitivity, specificity and diagnostic accuracy of Magnetic Resonance Cholangiography (MR-CP) in patients with suspected choledocholithiasis. Sixty-two patients (mean age: 56.3 years) previously submitted to US, were examined with MRCP. MR exams were performed with an 0.5 T superconductive magnet (Gyroscan T5-II; Philips, Medical System, Best, NL) and a body coil. 3D-TSE sequences (TR/TE/ETL = 5.000/244/45 ms) were acquired, with 14 min 10 sec acquisition time. In the last 21 patients, acquisition time was reduced down to 3 min, by optimizing the parameters as follows: TR/TE/ETL = 3.000/700/128 ms. The images, obtained on the coronal plane, were then reconstructed with the MIP algorithm. MRCP images were studied both as MIP reconstructions and as single slices. The diagnosis was always compared with endoscopic or percutaneous findings. MRCP images were of diagnostic quality in all cases, with 91.7% sensitivity, 100% specificity and 96.8% diagnostic accuracy. MRCP had 100% positive predictive value and 95% negative predictive value. In conclusion, this technique is extremely useful to examine the patients with obstructive jaundice secondary to lithiasis.
1996
adult
aged
aged: 80 and over
cholangiography
common bile duct
female
gallstones
humans
magnetic resonance imaging
male
middle aged
sensitivity and specificity
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/100893
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact