Purpose: In modern radiation therapy accurate small fields dosimetry is a challenge and its standardization is fundamental to harmonize delivered dose in different institutions. This study presents a multicenter characterization of MLC-defined small field for Elekta and Varian linear accelerators. Measurements were performed using the Exradin W1 plastic scintillator detector. Materials and methods: The project enrolled 24 Italian centers. Each center performed Tissue Phantom Ratio (TPR), in-plane and cross-plane dose profiles of 0.8 +/- 0.8 cm(2) field, and Output Factor (OF) measurements for square field sizes ranging from 0.8 to 10 cm. Set-up conditions were 10 cm depth in water phantom at SSD 90 cm. Measurements were performed using two twin Exradin W1 plastic scintillator detectors (PSD) correcting for the Cerenkov effect as proposed by the manufacturer. Results: Data analysis from 12 Varian and 12 Elekta centers was performed. Measurements of 7 centers were not included due to cable problems. TPR measurements showed standard deviations (SD) < 1%; SD < 0.4 mm for the profile penumbra was obtained, while FWHM measurements showed SD < 0.5 mm. OF measurements showed SD < 1.5% for field size greater than 2 x 2 cm(2). Median OFs values were in agreement with the recent bibliography. Conclusions: High degree of consistency was registered for all the considered parameters. This work confirmed the importance of multicenter dosimetric intercomparison. W1 PSD could be considered as a good candidate for small field measurements. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Dosimetric characterization of small fields using a plastic scintillator detector: A large multicenter study

Mancosu P;
2017-01-01

Abstract

Purpose: In modern radiation therapy accurate small fields dosimetry is a challenge and its standardization is fundamental to harmonize delivered dose in different institutions. This study presents a multicenter characterization of MLC-defined small field for Elekta and Varian linear accelerators. Measurements were performed using the Exradin W1 plastic scintillator detector. Materials and methods: The project enrolled 24 Italian centers. Each center performed Tissue Phantom Ratio (TPR), in-plane and cross-plane dose profiles of 0.8 +/- 0.8 cm(2) field, and Output Factor (OF) measurements for square field sizes ranging from 0.8 to 10 cm. Set-up conditions were 10 cm depth in water phantom at SSD 90 cm. Measurements were performed using two twin Exradin W1 plastic scintillator detectors (PSD) correcting for the Cerenkov effect as proposed by the manufacturer. Results: Data analysis from 12 Varian and 12 Elekta centers was performed. Measurements of 7 centers were not included due to cable problems. TPR measurements showed standard deviations (SD) < 1%; SD < 0.4 mm for the profile penumbra was obtained, while FWHM measurements showed SD < 0.5 mm. OF measurements showed SD < 1.5% for field size greater than 2 x 2 cm(2). Median OFs values were in agreement with the recent bibliography. Conclusions: High degree of consistency was registered for all the considered parameters. This work confirmed the importance of multicenter dosimetric intercomparison. W1 PSD could be considered as a good candidate for small field measurements. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/105228
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 17
social impact