Background: Electrosurgical laceration and stabilization of failed MitraClip(s) (ELASTA-Clip) has been proposed as a novel technique to cut the anterior mitral leaflet. A simplified transapical approach has been suggested. Case Summary: An 83-year-old man was admitted for recurrent, symptomatic mitral regurgitation after edge-to-edge (ETE) repair with PASCAL due to incomplete closure of the device. A transapical ELASTA failed despite multiple attempts. The procedure was then switched trans-septally and successfully performed without interference with the device. A transapical Tendyne was then implanted without any issue. Discussion: The case highlights that ELASTA can fail in case of transapical approach for possible wire impingement in the PASCAL. Take-Home Message: Transfemoral ELASTA should be preferred particularly in case of failed ETE due to partial closure of the ETE device.

Electrosurgical Laceration and Stabilization of a Failed Mitral Edge-to-Edge Device Before Transcatheter Mitral Valve Replacement: The Importance of a Trans-Septal Approach

Stefanini G. G.;
2025-01-01

Abstract

Background: Electrosurgical laceration and stabilization of failed MitraClip(s) (ELASTA-Clip) has been proposed as a novel technique to cut the anterior mitral leaflet. A simplified transapical approach has been suggested. Case Summary: An 83-year-old man was admitted for recurrent, symptomatic mitral regurgitation after edge-to-edge (ETE) repair with PASCAL due to incomplete closure of the device. A transapical ELASTA failed despite multiple attempts. The procedure was then switched trans-septally and successfully performed without interference with the device. A transapical Tendyne was then implanted without any issue. Discussion: The case highlights that ELASTA can fail in case of transapical approach for possible wire impingement in the PASCAL. Take-Home Message: Transfemoral ELASTA should be preferred particularly in case of failed ETE due to partial closure of the ETE device.
2025
edge to edge
electrosurgery
mitral regurgitation
transcatheter mitral valve replacement
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/108566
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact