Purpose: To evaluate the results of custom laser-assisted subepithelial keratectomy (LASEK) with a specially designed transition zone and smoothing for the treatment of refractive errors. Setting: Department of Ophthalmology, Istituto Clinico Humanitas, Rozzano-Milan, Italy. Methods: This prospective study involved myopic eyes having refractive surgery with the butterfly LASEK technique and the Nidek EC-5000 excimer laser. The treatment was based on the surgeon's analysis of topographic and aberrometric data provided by Final Fit ablation software, which features the Custom Aspheric Transition Zone software algorithm. After the ablation, smoothing was performed to remove corneal microirregularities. Results: Fifty-five eyes of 38 patients were treated. The mean preoperative spherical equivalent (SE) refraction was -6.58 diopters (D) ± 2.24 (SD) (range -12.13 to -1.75 D). At 1 year, the mean SE refraction was -0.26 ± 0.79 D (range -4.00 to +0.75 D). Conclusion: The surface ablation technique provided satisfactory results and took into account strategies to reduce unpredictability factors such as corneal biomechanical forces, haze induced by an irregular postoperative surface, and a high curvature gradient in the transition zone. © 2005 ASCRS and ESCRS. -------------------------------------------------------------------------------- Reaxys Database Information |

Transition zone design and smoothing in custom laser-assisted subepithelial keratectomy

Vinciguerra P;
2005-01-01

Abstract

Purpose: To evaluate the results of custom laser-assisted subepithelial keratectomy (LASEK) with a specially designed transition zone and smoothing for the treatment of refractive errors. Setting: Department of Ophthalmology, Istituto Clinico Humanitas, Rozzano-Milan, Italy. Methods: This prospective study involved myopic eyes having refractive surgery with the butterfly LASEK technique and the Nidek EC-5000 excimer laser. The treatment was based on the surgeon's analysis of topographic and aberrometric data provided by Final Fit ablation software, which features the Custom Aspheric Transition Zone software algorithm. After the ablation, smoothing was performed to remove corneal microirregularities. Results: Fifty-five eyes of 38 patients were treated. The mean preoperative spherical equivalent (SE) refraction was -6.58 diopters (D) ± 2.24 (SD) (range -12.13 to -1.75 D). At 1 year, the mean SE refraction was -0.26 ± 0.79 D (range -4.00 to +0.75 D). Conclusion: The surface ablation technique provided satisfactory results and took into account strategies to reduce unpredictability factors such as corneal biomechanical forces, haze induced by an irregular postoperative surface, and a high curvature gradient in the transition zone. © 2005 ASCRS and ESCRS. -------------------------------------------------------------------------------- Reaxys Database Information |
File in questo prodotto:
File Dimensione Formato  
VINCIGUERRA-Transition zone design.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non specificato
Dimensione 665.87 kB
Formato Adobe PDF
665.87 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/14380
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 24
social impact