The main purpose of the present study was to determine long-term implant fixation of 15 unicompartmental knee arthroplasty (UKAs) with an all-poly tibial component using Roentgen stereophotogrammetric analysis (RSA) at a mean 10-year follow-up. The secondary purpose was to investigate whether the progressive loss of implant's fixation correlates with a reduction in Knee society score (KSS). METHODS: Fifteen non-consecutive patients with primary knee osteoarthritis received a UKA with an all-poly tibial component were assessed using KSS scores pre-operatively and post-operatively and RSA on day 2 after surgery, then at 3, 6, and 12 months and yearly thereafter. The mean last follow-up was 10 years. RESULTS: An increase in maximum total point motion (MTPM) values from 6 months to 1 year post-operatively was found respect to post-operative reference. Implants' displacement values were always <2 mm during the first 6 months, and then, two different trends were noticed in revised and non-revised implants. MTPM increase between 1 and 2 years of follow-up in non-revised UKAs was always <0.2 mm, whereas it was >0.2 mm in revised UKAs. A linear and negative correlation with statistical significance was found between MTPM and both clinical and functional KSS scores (p < 0.001). CONCLUSION: Also in a long-term follow-up evaluation, RSA is an effective tool to predict functional results after an all-poly UKA providing also a relevant predictive value at 1 year follow-up, and this can be very useful for both patients and surgeons.

Roentgen stereophotogrammetric analysis: an effective tool to predict implant survival after an all-poly unicompartmental knee arthroplasty—a 10 year follow-up study

Marcacci Maurilio
2015-01-01

Abstract

The main purpose of the present study was to determine long-term implant fixation of 15 unicompartmental knee arthroplasty (UKAs) with an all-poly tibial component using Roentgen stereophotogrammetric analysis (RSA) at a mean 10-year follow-up. The secondary purpose was to investigate whether the progressive loss of implant's fixation correlates with a reduction in Knee society score (KSS). METHODS: Fifteen non-consecutive patients with primary knee osteoarthritis received a UKA with an all-poly tibial component were assessed using KSS scores pre-operatively and post-operatively and RSA on day 2 after surgery, then at 3, 6, and 12 months and yearly thereafter. The mean last follow-up was 10 years. RESULTS: An increase in maximum total point motion (MTPM) values from 6 months to 1 year post-operatively was found respect to post-operative reference. Implants' displacement values were always <2 mm during the first 6 months, and then, two different trends were noticed in revised and non-revised implants. MTPM increase between 1 and 2 years of follow-up in non-revised UKAs was always <0.2 mm, whereas it was >0.2 mm in revised UKAs. A linear and negative correlation with statistical significance was found between MTPM and both clinical and functional KSS scores (p < 0.001). CONCLUSION: Also in a long-term follow-up evaluation, RSA is an effective tool to predict functional results after an all-poly UKA providing also a relevant predictive value at 1 year follow-up, and this can be very useful for both patients and surgeons.
2015
All-poly tibial component unicompartmental knee arthroplasty
Implant fixation
Maximum total point motion
Roentgen stereophotogrammetric analysis
Orthopedics and Sports Medicine
Surgery
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/31668
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact