The aim of this case report was to present an endovascular treatment of a residual post-dissection Crawford type III thoracoabdominal aneurysm (TAA). A 60-year-old man, who had suffered from acute type B aortic dissection (TBAD) 8 years ago and had already been treated for both descending thoracic and infrarenal aortic aneurysm with open repair, presented with a 61mm post-dissection TAA. The aneurysm was successfully excluded with a staged fully endovascular procedure by employing two multibranched custom-made stent grafts deployed into the false lumen. The first stent-graft with a proximal monobranch was created to perfuse the right renal artery via the true lumen. The latter, with a triple branch design, was meant to perfuse the visceral arteries and left renal artery arising from the false lumen. Available branched custom-made stent-grafts for the treatment of degenerative TAA can be employed also in post TBAD aneurysms so as to simplify the procedure. The branched stent-grafts could be deployed within an enlarged false lumen provided that a suitable distal landing zone is available as well as that the visceral vessels can be perfused from the false lumen. A proximal branch for perfusing one of the lumens of the dissection from the proximal tear can be an alternative solution to creating neofenestrations.

Branched stent-grafts deployed in the true and false lumen to exclude a post dissecting thoracoabdominal aneurysm

Civilini E;
2016-01-01

Abstract

The aim of this case report was to present an endovascular treatment of a residual post-dissection Crawford type III thoracoabdominal aneurysm (TAA). A 60-year-old man, who had suffered from acute type B aortic dissection (TBAD) 8 years ago and had already been treated for both descending thoracic and infrarenal aortic aneurysm with open repair, presented with a 61mm post-dissection TAA. The aneurysm was successfully excluded with a staged fully endovascular procedure by employing two multibranched custom-made stent grafts deployed into the false lumen. The first stent-graft with a proximal monobranch was created to perfuse the right renal artery via the true lumen. The latter, with a triple branch design, was meant to perfuse the visceral arteries and left renal artery arising from the false lumen. Available branched custom-made stent-grafts for the treatment of degenerative TAA can be employed also in post TBAD aneurysms so as to simplify the procedure. The branched stent-grafts could be deployed within an enlarged false lumen provided that a suitable distal landing zone is available as well as that the visceral vessels can be perfused from the false lumen. A proximal branch for perfusing one of the lumens of the dissection from the proximal tear can be an alternative solution to creating neofenestrations.
File in questo prodotto:
File Dimensione Formato  
R37Y2016N05A0646.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 2.27 MB
Formato Adobe PDF
2.27 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/5192
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact