To complement RT-qPCR testing for diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections, many countries have introduced the use of rapid antigen tests. As they generally display lower real-life performances than expected, their correct positioning as frontline screening is still controversial. Despite the lack of data from daily clinical use, third generation microfluidic assays (such as the LumiraDx SARS-CoV-2 Ag test) have recently been suggested to have similar performances to RT-qPCR and have been proposed as alternative diagnostic tools. By analyzing 960 nasopharyngeal swabs from 960 subjects at the emergency department admissions of a tertiary COVID-19 hospital, LumiraDx assay demonstrated a specificity of 97% (95% CI: 96-98), and a sensitivity of 85% (95% CI: 82-89) in comparison with RT-qPCR, which increases to 91% (95% CI: 86-95) for samples with a cycle threshold <= 29. Fifty false-negative LumiraDx-results were confirmed by direct quantification of genomic SARS-CoV-2 RNA through droplet-digital PCR (median (IQR) load = 5880 (1657-41,440) copies/mL). Subgenomic N and E RNAs were detected in 52% (n = 26) and 56% (n = 28) of them, respectively, supporting the presence of active viral replication. Overall, the LumiraDx test complies with the minimum performance requirements of the WHO. Yet, the risk of a misrecognition of patients with active COVID-19 persists, and the need for confirmatory RT-qPCR should not be amended.

Frontline Screening for SARS-CoV-2 Infection at Emergency Department Admission by Third Generation Rapid Antigen Test: Can We Spare RT-qPCR?

Cento, Valeria;
2021-01-01

Abstract

To complement RT-qPCR testing for diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections, many countries have introduced the use of rapid antigen tests. As they generally display lower real-life performances than expected, their correct positioning as frontline screening is still controversial. Despite the lack of data from daily clinical use, third generation microfluidic assays (such as the LumiraDx SARS-CoV-2 Ag test) have recently been suggested to have similar performances to RT-qPCR and have been proposed as alternative diagnostic tools. By analyzing 960 nasopharyngeal swabs from 960 subjects at the emergency department admissions of a tertiary COVID-19 hospital, LumiraDx assay demonstrated a specificity of 97% (95% CI: 96-98), and a sensitivity of 85% (95% CI: 82-89) in comparison with RT-qPCR, which increases to 91% (95% CI: 86-95) for samples with a cycle threshold <= 29. Fifty false-negative LumiraDx-results were confirmed by direct quantification of genomic SARS-CoV-2 RNA through droplet-digital PCR (median (IQR) load = 5880 (1657-41,440) copies/mL). Subgenomic N and E RNAs were detected in 52% (n = 26) and 56% (n = 28) of them, respectively, supporting the presence of active viral replication. Overall, the LumiraDx test complies with the minimum performance requirements of the WHO. Yet, the risk of a misrecognition of patients with active COVID-19 persists, and the need for confirmatory RT-qPCR should not be amended.
2021
SARS-CoV-2
antigenic test
infectivity
rapid diagnostic test
subgenomic RNA
viral load
Aged
Antigens, Viral
COVID-19
COVID-19 Testing
Emergency Service, Hospital
Female
Humans
Italy
Male
Microfluidic Analytical Techniques
Middle Aged
Nasopharynx
RNA, Viral
Real-Time Polymerase Chain Reaction
SARS-CoV-2
Sensitivity and Specificity
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/65201
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 15
social impact