BackgroundTranscatheter heart valve thrombosis (THV-t) and endocarditis (THV-e) are relevant complications after transcatheter aortic valve implantation (TAVI). Transcatheter heart valve (THV) dysfunction definition is mostly based on Doppler (stenosis/regurgitation) without considering leaflets characteristics.PurposeTo evaluate the additional diagnostic value of leaflets echocardiographic features over Doppler when prosthetic valve complication is suspected.MethodsAmong 621 post-TAVI patients, 128 cases with probable valve complication were identified. THV-t was finally diagnosed in 13 patients (10%) and THV-e in 8 (6%), while the remaining 107 (84%) had no definitive diagnosis of thrombosis/endocarditis (THV-no). We analyzed at 2 time points (baseline and follow-up) both traditional Doppler parameters and leaflets morpho-functional features.ResultsBoth Doppler and leaflets parameters showed high sensitivity (sensitivity 92%) and low specificity (ranging from specificity 32% to 74%) in detecting THV-t. Interestingly, the combination of mean aortic pressure gradient 20mmHg and leaflet thickening significantly improved the specificity of echocardiography for diagnosis of THV thrombosis (specificity 94%). On the other hand, echocardiographic diagnosis of THV endocarditis remained limited by very low sensitivity despite showing high specificity.ConclusionsThe combination of Doppler and leaflets parameters can improve the echocardiographic diagnosis of THV thrombosis in post-TAVI patients with suspicious symptoms, via a significant increase in the overall test specificity. This would potentially allow more rational gatekeeping to more expensive/invasive diagnostic examinations (eg, CT scan) or therapeutic trials (eg, unnecessary anticoagulation).

Echocardiographic features of post-transcatheter aortic valve implantation thrombosis and endocarditis

Colombo, Antonio;
2018-01-01

Abstract

BackgroundTranscatheter heart valve thrombosis (THV-t) and endocarditis (THV-e) are relevant complications after transcatheter aortic valve implantation (TAVI). Transcatheter heart valve (THV) dysfunction definition is mostly based on Doppler (stenosis/regurgitation) without considering leaflets characteristics.PurposeTo evaluate the additional diagnostic value of leaflets echocardiographic features over Doppler when prosthetic valve complication is suspected.MethodsAmong 621 post-TAVI patients, 128 cases with probable valve complication were identified. THV-t was finally diagnosed in 13 patients (10%) and THV-e in 8 (6%), while the remaining 107 (84%) had no definitive diagnosis of thrombosis/endocarditis (THV-no). We analyzed at 2 time points (baseline and follow-up) both traditional Doppler parameters and leaflets morpho-functional features.ResultsBoth Doppler and leaflets parameters showed high sensitivity (sensitivity 92%) and low specificity (ranging from specificity 32% to 74%) in detecting THV-t. Interestingly, the combination of mean aortic pressure gradient 20mmHg and leaflet thickening significantly improved the specificity of echocardiography for diagnosis of THV thrombosis (specificity 94%). On the other hand, echocardiographic diagnosis of THV endocarditis remained limited by very low sensitivity despite showing high specificity.ConclusionsThe combination of Doppler and leaflets parameters can improve the echocardiographic diagnosis of THV thrombosis in post-TAVI patients with suspicious symptoms, via a significant increase in the overall test specificity. This would potentially allow more rational gatekeeping to more expensive/invasive diagnostic examinations (eg, CT scan) or therapeutic trials (eg, unnecessary anticoagulation).
2018
echocardiography
endocarditis
thrombosis
transcatheter aortic valve implantation (TAVI)
Aged
Aged
80 and over
Aortic Valve
Coronary Thrombosis
Echocardiography
Endocarditis
Female
Humans
Male
Sensitivity and Specificity
Treatment Outcome
Heart Valve Prosthesis
Transcatheter Aortic Valve Replacement
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/75078
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact