BACKGROUND: To date, no scale has been validated to assess bubbles associated with bowel preparation. This study aimed to develop and assess the reliability of a novel scale - the Colon Endoscopic Bubble Scale (CEBuS). METHODS: This was a multicenter, prospective, observational study with two online evaluation phases of 45 randomly distributed still colonoscopy images (15 per scale grade). Observers assessed images twice, 2 weeks apart, using CEBuS (CEBuS-0 - no or minimal bubbles, covering < 5 % of the surface; CEBuS-1 - bubbles covering 5 %-50 %; CEBuS-2 - bubbles covering > 50 %) and reporting the clinical action (do nothing; wash with water; wash with simethicone). RESULTS: CEBuS provided high levels of agreement both in evaluation Phase 1 (4 experts) and Phase 2 (6 experts and 13 non-experts), with almost perfect intraobserver reliability: kappa 0.82 (95 % confidence interval 0.75-0.88) and 0.86 (0.85-0.88); interobserver agreement - intraclass correlation coefficient (ICC) 0.83 (0.73-0.89) and 0.90 (0.86-0.94). Previous endoscopic experience had no influence on agreement among experts vs. non-experts: kappa 0.86 (0.80-0.91) vs. 0.87 (0.84-0.89) and ICC 0.91 (0.87-0.94) vs. 0.90 (0.86-0.94), respectively. Interobserver agreement on clinical action was ICC 0.63 (0.43-0.78) in Phase 1 and 0.77 (0.68-0.84) in Phase 2. Absolute agreement on clinical action per scale grade was 85 % (82-88) for CEBuS-0, 21 % (16-26) for CEBuS-1, and 74 % (70-78) for CEBuS-2. CONCLUSION: CEBuS proved to be a reliable instrument to standardize the evaluation of colonic bubbles during colonoscopy. Assessment in daily practice is warranted.

The Colon Endoscopic Bubble Scale (CEBuS): a two-phase evaluation study

Hassan C;
2020-01-01

Abstract

BACKGROUND: To date, no scale has been validated to assess bubbles associated with bowel preparation. This study aimed to develop and assess the reliability of a novel scale - the Colon Endoscopic Bubble Scale (CEBuS). METHODS: This was a multicenter, prospective, observational study with two online evaluation phases of 45 randomly distributed still colonoscopy images (15 per scale grade). Observers assessed images twice, 2 weeks apart, using CEBuS (CEBuS-0 - no or minimal bubbles, covering < 5 % of the surface; CEBuS-1 - bubbles covering 5 %-50 %; CEBuS-2 - bubbles covering > 50 %) and reporting the clinical action (do nothing; wash with water; wash with simethicone). RESULTS: CEBuS provided high levels of agreement both in evaluation Phase 1 (4 experts) and Phase 2 (6 experts and 13 non-experts), with almost perfect intraobserver reliability: kappa 0.82 (95 % confidence interval 0.75-0.88) and 0.86 (0.85-0.88); interobserver agreement - intraclass correlation coefficient (ICC) 0.83 (0.73-0.89) and 0.90 (0.86-0.94). Previous endoscopic experience had no influence on agreement among experts vs. non-experts: kappa 0.86 (0.80-0.91) vs. 0.87 (0.84-0.89) and ICC 0.91 (0.87-0.94) vs. 0.90 (0.86-0.94), respectively. Interobserver agreement on clinical action was ICC 0.63 (0.43-0.78) in Phase 1 and 0.77 (0.68-0.84) in Phase 2. Absolute agreement on clinical action per scale grade was 85 % (82-88) for CEBuS-0, 21 % (16-26) for CEBuS-1, and 74 % (70-78) for CEBuS-2. CONCLUSION: CEBuS proved to be a reliable instrument to standardize the evaluation of colonic bubbles during colonoscopy. Assessment in daily practice is warranted.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/75681
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact