PURPOSE:The purpose of this study was to compare contrast enhanced MR angiography (MRA) with gadopentetate dimeglumine (Gd-DTPA) to MRA with gadobenate dimeglumine (Gd-BOPTA), a high relaxivity paramagnetic contrast agent.MATERIALS AND METHODS:Twelve patients referred for carotid artery stenosis were examined with MR angiography using a fast spoiled gradient echo sequence. Gd-DTPA and Gd-BOPTA enhanced MR angiography were performed within 48-72 hours using a dose of 0.1 mmol/kg for Gd-BOPTA and 0.2 mmol/kg for Gd-DTPA, at a flow rate of 2 ml/s. Images were evaluated by two blinded radiologists. Qualitative and quantitative evaluations were performed comparing the sets of images from the two examinations.RESULTS:Qualitative evaluation demonstrated superior arterial contrast enhancement and vessel conspicuity with Gd-BOPTA compared with Gd-DTPA. Quantita-tive evaluation showed an improvement in both signal intensity and contrast to noise ratio with Gd-BOPTA.CONCLUSION:The greater relaxivity of Gd-BOPTA, at lower doses, compared with Gd-DTPA, provides higher intravascular signal and signal to noise ratio. Gd-BOPTA appears to be an optimal contrast agent for contrast enhanced MRA

Gadobenate dimeglumine (Gd-DTPA) vs gadopentetate dimeglumine (Gd-BOPTA) for contrast-enhanced magnetic resonance angiography (MRA): improvement in intravascular signal intensity and contrast to noise ratio

FRANCONE, MARCO;
2003-01-01

Abstract

PURPOSE:The purpose of this study was to compare contrast enhanced MR angiography (MRA) with gadopentetate dimeglumine (Gd-DTPA) to MRA with gadobenate dimeglumine (Gd-BOPTA), a high relaxivity paramagnetic contrast agent.MATERIALS AND METHODS:Twelve patients referred for carotid artery stenosis were examined with MR angiography using a fast spoiled gradient echo sequence. Gd-DTPA and Gd-BOPTA enhanced MR angiography were performed within 48-72 hours using a dose of 0.1 mmol/kg for Gd-BOPTA and 0.2 mmol/kg for Gd-DTPA, at a flow rate of 2 ml/s. Images were evaluated by two blinded radiologists. Qualitative and quantitative evaluations were performed comparing the sets of images from the two examinations.RESULTS:Qualitative evaluation demonstrated superior arterial contrast enhancement and vessel conspicuity with Gd-BOPTA compared with Gd-DTPA. Quantita-tive evaluation showed an improvement in both signal intensity and contrast to noise ratio with Gd-BOPTA.CONCLUSION:The greater relaxivity of Gd-BOPTA, at lower doses, compared with Gd-DTPA, provides higher intravascular signal and signal to noise ratio. Gd-BOPTA appears to be an optimal contrast agent for contrast enhanced MRA
2003
Carotid Stenosis
diagnosis
Contrast Media
Gadolinium DTPA
Humans
Magnetic Resonance Angiography
Meglumine
analogs /&/ derivatives
Organometallic Compounds
Statistics
Nonparametric.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/77924
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? ND
social impact