INTRODUCTION: The majority of patients with nonischemic cardiomyopathy (NICM) present a perivalvular substrate that is either predominantly antero-septal (AS) or infero-lateral (IL), corresponding to specific ventricular tachycardia (VT) morphologies. The relative timing of far-field and near-field ventricular electrograms (EGMs) from stored implantable cardioverter-defibrillator (ICD) events of VT may be used to distinguish AS from IL VT in NICM.; METHODS AND RESULTS: We analyzed 48 patients with NICM with either a primarily AS (54%) or IL (56%) VT source undergoing catheter ablation between 2003 and 2018. Only patients with retrievable ICD-EGMs of spontaneous VT events which could be matched with VTs induced during the ablation procedure were included. A total of 56 VT events (52% AS origin and 48% IL origin) were analyzed, yielding a mean far-field to near-field interval of 31±13milliseconds for AS VTs and 47±19milliseconds for IL VTs (P=.001). At receiver operating characteristic analysis (AUC=0.734), a far-field to near-field interval of≥60milliseconds ruled out AS VTs in 29 (100%) cases and diagnosed IL VTs with a positive predictive value (PPV) of 100% and a negative predictive value (NPV) of 63%. An interval of≤20milliseconds ruled out IL VTs in 25 (93%) cases and diagnosed AS VTs with a PPV of 83% and NPV of 57%. Significant overlap between the two groups was observed among far-field to near-field intervals in between 20milliseconds and 60milliseconds.; CONCLUSIONS: The relative timing of far-field and near-field EGMs from stored clinical ICD events of VT can be helpful to differentiate AS vs IL origin of VT in NICM. © 2019 Wiley Periodicals, Inc.

Ventricular tachycardia in nonischemic cardiomyopathy: Anteroseptal vs inferolateral origin based on ICD ventricular electrogram timing

Muser D;
In corso di stampa

Abstract

INTRODUCTION: The majority of patients with nonischemic cardiomyopathy (NICM) present a perivalvular substrate that is either predominantly antero-septal (AS) or infero-lateral (IL), corresponding to specific ventricular tachycardia (VT) morphologies. The relative timing of far-field and near-field ventricular electrograms (EGMs) from stored implantable cardioverter-defibrillator (ICD) events of VT may be used to distinguish AS from IL VT in NICM.; METHODS AND RESULTS: We analyzed 48 patients with NICM with either a primarily AS (54%) or IL (56%) VT source undergoing catheter ablation between 2003 and 2018. Only patients with retrievable ICD-EGMs of spontaneous VT events which could be matched with VTs induced during the ablation procedure were included. A total of 56 VT events (52% AS origin and 48% IL origin) were analyzed, yielding a mean far-field to near-field interval of 31±13milliseconds for AS VTs and 47±19milliseconds for IL VTs (P=.001). At receiver operating characteristic analysis (AUC=0.734), a far-field to near-field interval of≥60milliseconds ruled out AS VTs in 29 (100%) cases and diagnosed IL VTs with a positive predictive value (PPV) of 100% and a negative predictive value (NPV) of 63%. An interval of≤20milliseconds ruled out IL VTs in 25 (93%) cases and diagnosed AS VTs with a PPV of 83% and NPV of 57%. Significant overlap between the two groups was observed among far-field to near-field intervals in between 20milliseconds and 60milliseconds.; CONCLUSIONS: The relative timing of far-field and near-field EGMs from stored clinical ICD events of VT can be helpful to differentiate AS vs IL origin of VT in NICM. © 2019 Wiley Periodicals, Inc.
In corso di stampa
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/83264
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact