Background: Persistent air leak is a common complication after lung resection causing prolonged length of stay and increased healthcare costs. Surgical intervention can be an option, but other more conservative approaches should be considered first. Here, we describe the use of flexible bronchoscopy to apply fibrin glue and autologous blood sequentially to the damaged lung. We named the technique "flexible thoracoscopy". Methods: Medical records from patients with persistent air leaks after lung resection were collected retrospectively. Depending on the type of aerostasis that was performed, two groups were created: flexible thoracoscopy and surgery (thoracotomy). Flexible thoracoscopy was introduced at our institution in 2013. We entered the pleural space with a bronchoscope following the same surgical pathway that was used for tube thoracostomy. Perioperative characteristics and outcomes were analyzed using R software (ver. 3.4.4). Results: From 1997 to 2021, a total of 23 patients required an intervention for persistent air leaks. Aerostasis was performed via flexible thoracoscopy in seventeen patients (69%) and via thoracotomy in six patients (31%). The median age was 70 years (22-82). Twenty patients were males (87%). There was no difference in age, sex distribution, BMI, comorbidities and FEV1%. An ASA score of 3 was more represented in the flexible thoracoscopy group; however, no evidence of a difference was found when compared to the thoracotomy group (p = 0.124). Length of in-hospital stay and chest tube duration was also similar between groups (p = 1 and p = 0.68, respectively). Conclusions: Aerostasis achieved either by flexible thoracoscopy or by thoracotomy showed similar results. We believe that flexible thoracoscopy could be a valid alternative to facilitate minimally invasive treatments for persistent air leaks. Further studies are needed to confirm these results.

Bronchoscopic Intra-Pleural Instillation of Fibrin Glue and Autologous Blood to Manage Persistent Air Leaks after Lung Resection

Alloisio, Marco;
2022-01-01

Abstract

Background: Persistent air leak is a common complication after lung resection causing prolonged length of stay and increased healthcare costs. Surgical intervention can be an option, but other more conservative approaches should be considered first. Here, we describe the use of flexible bronchoscopy to apply fibrin glue and autologous blood sequentially to the damaged lung. We named the technique "flexible thoracoscopy". Methods: Medical records from patients with persistent air leaks after lung resection were collected retrospectively. Depending on the type of aerostasis that was performed, two groups were created: flexible thoracoscopy and surgery (thoracotomy). Flexible thoracoscopy was introduced at our institution in 2013. We entered the pleural space with a bronchoscope following the same surgical pathway that was used for tube thoracostomy. Perioperative characteristics and outcomes were analyzed using R software (ver. 3.4.4). Results: From 1997 to 2021, a total of 23 patients required an intervention for persistent air leaks. Aerostasis was performed via flexible thoracoscopy in seventeen patients (69%) and via thoracotomy in six patients (31%). The median age was 70 years (22-82). Twenty patients were males (87%). There was no difference in age, sex distribution, BMI, comorbidities and FEV1%. An ASA score of 3 was more represented in the flexible thoracoscopy group; however, no evidence of a difference was found when compared to the thoracotomy group (p = 0.124). Length of in-hospital stay and chest tube duration was also similar between groups (p = 1 and p = 0.68, respectively). Conclusions: Aerostasis achieved either by flexible thoracoscopy or by thoracotomy showed similar results. We believe that flexible thoracoscopy could be a valid alternative to facilitate minimally invasive treatments for persistent air leaks. Further studies are needed to confirm these results.
2022
blood patch
bronchoscopy
fibrin glue
flexible thoracoscopy
lung resection
persistent air leak
prolonged air leak
prolonged length of stay
thoracic surgery
thoracotomy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/83691
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 1
social impact