Purpose: To establish the safety and efficacy of gantry-mounted linear accelerator-based stereotactic body radiation therapy (SBRT) for low- and intermediate-risk prostate cancer. Methods: We pooled 921 patients enrolled on 7 single-institution prospective phase II trials of gantry-based SBRT from 2006 to 2017. The cumulative incidences of biochemical recurrence (defined by the Phoenix definition) and physician-scored genitourinary (GU) and gastrointestinal (GI) toxicities (defined per the original trials using Common Terminology Criteria for Adverse Events) were estimated using a competing risk framework. Multivariable logistic regression was used to evaluate the relationship between late toxicity and prespecified covariates: biologically effective dose, every other day versus weekly fractionation, intrafractional motion monitoring, and acute toxicity. Results: Median follow-up was 3.1 years (range, 0.5-10.8 years). In addition, 505 (54.8%) patients had low-risk disease, 236 (25.6%) had favorable intermediate-risk disease, and 180 (19.5%) had unfavorable intermediate-risk disease. Intrafractional motion monitoring was performed in 78.0% of patients. The 3-year cumulative incidence of biochemical recurrence was 0.8% (95% confidence interval [CI], 0-1.7%), 2.2% (95% CI, 0-4.3%), and 5.1% (95% CI, 1.0-9.2%) for low-, favorable intermediate-, and unfavorable intermediate-risk disease. Acute grade ≥2 GU and GI toxicity occurred in 14.5% and 4.6% of patients, respectively. Three-year cumulative incidence estimates of late grade 2 GU and GI toxicity were 4.1% (95% CI, 2.6-5.5%) and 1.3% (95% CI, 0.5-2.1%), respectively, with late grade ≥3 GU and GI toxicity estimates of 0.7% (95% CI, 0.1-1.3%) and 0.4% (95% CI, 0-0.8%), respectively. The only identified significant predictors of late grade ≥2 toxicity were acute grade ≥2 toxicity (P < .001) and weekly fractionation (P < .01), although only 12.4% of patients were treated weekly. Conclusions: Gantry-based SBRT for prostate cancer is associated with a favorable safety and efficacy profile, despite variable intrafractional motion management techniques. These findings suggest that multiple treatment platforms can be used to safely deliver prostate SBRT.

Gantry-Mounted Linear Accelerator–Based Stereotactic Body Radiation Therapy for Low- and Intermediate-Risk Prostate Cancer

Scorsetti, Marta;
2020-01-01

Abstract

Purpose: To establish the safety and efficacy of gantry-mounted linear accelerator-based stereotactic body radiation therapy (SBRT) for low- and intermediate-risk prostate cancer. Methods: We pooled 921 patients enrolled on 7 single-institution prospective phase II trials of gantry-based SBRT from 2006 to 2017. The cumulative incidences of biochemical recurrence (defined by the Phoenix definition) and physician-scored genitourinary (GU) and gastrointestinal (GI) toxicities (defined per the original trials using Common Terminology Criteria for Adverse Events) were estimated using a competing risk framework. Multivariable logistic regression was used to evaluate the relationship between late toxicity and prespecified covariates: biologically effective dose, every other day versus weekly fractionation, intrafractional motion monitoring, and acute toxicity. Results: Median follow-up was 3.1 years (range, 0.5-10.8 years). In addition, 505 (54.8%) patients had low-risk disease, 236 (25.6%) had favorable intermediate-risk disease, and 180 (19.5%) had unfavorable intermediate-risk disease. Intrafractional motion monitoring was performed in 78.0% of patients. The 3-year cumulative incidence of biochemical recurrence was 0.8% (95% confidence interval [CI], 0-1.7%), 2.2% (95% CI, 0-4.3%), and 5.1% (95% CI, 1.0-9.2%) for low-, favorable intermediate-, and unfavorable intermediate-risk disease. Acute grade ≥2 GU and GI toxicity occurred in 14.5% and 4.6% of patients, respectively. Three-year cumulative incidence estimates of late grade 2 GU and GI toxicity were 4.1% (95% CI, 2.6-5.5%) and 1.3% (95% CI, 0.5-2.1%), respectively, with late grade ≥3 GU and GI toxicity estimates of 0.7% (95% CI, 0.1-1.3%) and 0.4% (95% CI, 0-0.8%), respectively. The only identified significant predictors of late grade ≥2 toxicity were acute grade ≥2 toxicity (P < .001) and weekly fractionation (P < .01), although only 12.4% of patients were treated weekly. Conclusions: Gantry-based SBRT for prostate cancer is associated with a favorable safety and efficacy profile, despite variable intrafractional motion management techniques. These findings suggest that multiple treatment platforms can be used to safely deliver prostate SBRT.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/91067
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact