Objectives: CT pulmonary angiography is the gold standard for diagnosing pulmonary embolism, and DL algorithms are being developed to manage the increase in demand. The nnU-Net is a new auto-adaptive DL framework that minimizes manual tuning, making it easier to develop effective algorithms for medical imaging even without specific expertise. This study assesses the performance of a locally developed nnU-Net algorithm on the RSPECT dataset for PE detection, clot volume measurement, and correlation with right ventricle overload. Materials & methods: User input was limited to segmentation using 3DSlicer. We worked with the RSPECT dataset and trained an algorithm from 205 PE and 340 negatives. The test dataset comprised 6573 exams. Performance was tested against PE characteristics, such as central, non-central, and RV overload. Blood clot volume (BCV) was extracted from each exam. We employed ROC curves and logistic regression for statistical validation. Results: Negative studies had a median BCV of 1 μL, which increased to 345 μL in PE-positive cases and 7,378 μL in central PEs. Statistical analysis confirmed a significant BCV correlation with PE presence, central PE, and increased RV/LV ratio (p < 0.0001). The model's AUC for PE detection was 0.865, with an 83 % accuracy at a 55 μL threshold. Central PE detection AUC was 0.937 with 91 % accuracy at 850 μL. The RV overload AUC stood at 0.848 with 79 % accuracy. Conclusion: The nnU-Net algorithm demonstrated accurate PE detection, particularly for central PE. BCV is an accurate metric for automated severity stratification and case prioritization. Clinical relevance statement: The nnU-Net framework can be utilized to create a dependable DL for detecting PE. It offers a user-friendly approach to those lacking expertise in AI and rapidly extracts the Blood Clot Volume, a metric that can evaluate the PE's severity.

nnU-Net-based deep-learning for pulmonary embolism: detection, clot volume quantification, and severity correlation in the RSPECT dataset

Lanza, Ezio;Francone, Marco
2024-01-01

Abstract

Objectives: CT pulmonary angiography is the gold standard for diagnosing pulmonary embolism, and DL algorithms are being developed to manage the increase in demand. The nnU-Net is a new auto-adaptive DL framework that minimizes manual tuning, making it easier to develop effective algorithms for medical imaging even without specific expertise. This study assesses the performance of a locally developed nnU-Net algorithm on the RSPECT dataset for PE detection, clot volume measurement, and correlation with right ventricle overload. Materials & methods: User input was limited to segmentation using 3DSlicer. We worked with the RSPECT dataset and trained an algorithm from 205 PE and 340 negatives. The test dataset comprised 6573 exams. Performance was tested against PE characteristics, such as central, non-central, and RV overload. Blood clot volume (BCV) was extracted from each exam. We employed ROC curves and logistic regression for statistical validation. Results: Negative studies had a median BCV of 1 μL, which increased to 345 μL in PE-positive cases and 7,378 μL in central PEs. Statistical analysis confirmed a significant BCV correlation with PE presence, central PE, and increased RV/LV ratio (p < 0.0001). The model's AUC for PE detection was 0.865, with an 83 % accuracy at a 55 μL threshold. Central PE detection AUC was 0.937 with 91 % accuracy at 850 μL. The RV overload AUC stood at 0.848 with 79 % accuracy. Conclusion: The nnU-Net algorithm demonstrated accurate PE detection, particularly for central PE. BCV is an accurate metric for automated severity stratification and case prioritization. Clinical relevance statement: The nnU-Net framework can be utilized to create a dependable DL for detecting PE. It offers a user-friendly approach to those lacking expertise in AI and rapidly extracts the Blood Clot Volume, a metric that can evaluate the PE's severity.
2024
Artificial intelligence
Computed tomography angiography
Deep learning
Pulmonary embolism
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11699/91329
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact