BackgroundSelf-expanding metal stents are frequently used for the palliation of malignant dysphagia. Recently, a new stent design, the Evolution stent (Cook Medical, Limerick, Ireland), was developed. The stent has an internal and external silicone coating to resist tissue ingrowth and uncoated dual flanges on both ends to prevent migration. Its controlled-release system may allow full control and precise positioning of the stent.ObjectiveTo determine the safety and clinical effectiveness of the Evolution stent for the palliation of dysphagia in patients with malignant strictures located in the esophagus (n = 33 [75%]) or gastric cardia (n = 11 [25%]).MethodsAll patients who underwent placement of an esophageal Evolution stent from February to December 2008 received follow-up telephone calls 14 days after treatment and thereafter monthly until death. Data on technical and clinical outcome, complications, and recurrent dysphagia were collected.ResultsA total of 44 patients (32 [73%] men, median age 74 years [range 48-91 years]) were treated with the Evolution stent. The median tumor length was 6 cm (range 1-11 cm). Stent placement was technically successful in 41 patients. Dysphagia improved from a median of 3 (ability to swallow liquids only) to 1 (ability to eat some solid foods) 4 weeks after stent placement. Major complications occurred in 4 (9%) patients, ie, pneumonia (3 patients) and hemorrhage (1 patient). Two (5%) patients died of pneumonia. Minor complications included gastroesophageal reflux and mild retrosternal pain in 11 (25%) and 4 (9%) patients, respectively. Recurrent dysphagia developed in 11 (25%) patients as a result of tissue ingrowth or overgrowth (6 patients; 14%), food impaction (3 patients; 7%), or stent migration (2 patients; 5%).ConclusionsThe Evolution stent is safe and effective for the palliation of dysphagia from esophageal and gastric cardia cancer. Randomized trials are needed to compare this device with other stent designs
A new metal stent with a controlled-release system for palliation of malignant dysphagia a prospective, multicenter study
A. Repici;A. Malesci;
2010-01-01
Abstract
BackgroundSelf-expanding metal stents are frequently used for the palliation of malignant dysphagia. Recently, a new stent design, the Evolution stent (Cook Medical, Limerick, Ireland), was developed. The stent has an internal and external silicone coating to resist tissue ingrowth and uncoated dual flanges on both ends to prevent migration. Its controlled-release system may allow full control and precise positioning of the stent.ObjectiveTo determine the safety and clinical effectiveness of the Evolution stent for the palliation of dysphagia in patients with malignant strictures located in the esophagus (n = 33 [75%]) or gastric cardia (n = 11 [25%]).MethodsAll patients who underwent placement of an esophageal Evolution stent from February to December 2008 received follow-up telephone calls 14 days after treatment and thereafter monthly until death. Data on technical and clinical outcome, complications, and recurrent dysphagia were collected.ResultsA total of 44 patients (32 [73%] men, median age 74 years [range 48-91 years]) were treated with the Evolution stent. The median tumor length was 6 cm (range 1-11 cm). Stent placement was technically successful in 41 patients. Dysphagia improved from a median of 3 (ability to swallow liquids only) to 1 (ability to eat some solid foods) 4 weeks after stent placement. Major complications occurred in 4 (9%) patients, ie, pneumonia (3 patients) and hemorrhage (1 patient). Two (5%) patients died of pneumonia. Minor complications included gastroesophageal reflux and mild retrosternal pain in 11 (25%) and 4 (9%) patients, respectively. Recurrent dysphagia developed in 11 (25%) patients as a result of tissue ingrowth or overgrowth (6 patients; 14%), food impaction (3 patients; 7%), or stent migration (2 patients; 5%).ConclusionsThe Evolution stent is safe and effective for the palliation of dysphagia from esophageal and gastric cardia cancer. Randomized trials are needed to compare this device with other stent designsI documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.